AC Load Bank · Permanent

Stationary Outdoor Load Bank

A weatherproof load bank on a pad beside the generator, wired in permanently with remote and automatic test control. 100 – 3,000 kW, Type 3R.

100 – 3,000 kWType 3R outdoorVertical dischargeRemote controlAuto exercise
3 MW
Max rating
3R
Enclosure
Remote
Control
Auto
Exercise mode
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Testing Built Into the Site

When a generator is tested monthly and the building rarely loads it heavily, a permanent load bank pays for itself. It sits on a pad, wired to the generator output through a breaker. During a test it adds load automatically so the generator always runs at a healthy level, and if a real outage happens it drops off so the building gets full power. Vertical discharge sends the heat straight up and away from the generator air intake.

  • Permanently connected through a breaker
  • Automatic load-following during exercise
  • Drops off when the building needs the power
  • Vertical hot-air discharge
  • Remote control from the generator room or BMS
  • Snow and rain-hood options
FIG. 02
Stationary Outdoor Load BankDWGCE-LDB-03-01VIEWHook-UpSCALENTSREV ACANDRON
Stationary Outdoor Load Bank · 100 – 3,000 kW · 208 – 600 V
In Plain Words

Stationary Outdoor Load Bank in plain words

What it does

A permanently installed, weatherproof load bank wired to the generator, so monthly and annual tests are a button press away.

Pick it when

  • The generator is tested often and the building load is too small
  • You want to test without hauling equipment in
  • The site has a pad beside the generator

Better choice if…

You test at many sites

See the Portable Resistive →
Features & Upgrades

What's Included

Standard Features
  • Heavy-gauge powder-coated steel, Type 3R
  • Weather-protected resistive elements
  • Cooling fans with motor protection
  • Over-temperature, loss-of-airflow, fan-motor overload and control-power-loss protection; element fusing
  • Control station with metering
Optional Upgrades
  • +Automatic exercise controller tied to the transfer switch
  • +BMS or SCADA integration
  • +Radiator-mounted design
  • +Stainless-steel construction
Technical Specifications

Full Specifications

ParameterValue
Rating100 – 3,000 kW
Voltage208 – 600 V AC
Load typeResistive
DischargeVertical
EnclosureType 3R outdoor
ControlLocal panel with kW, V, A, Hz readout; optional remote controller and PC software with data logging
Standards & Compliance

Built to Standard

CSA C282
Emergency electrical power supply for buildings — includes periodic load testing
CSA Z32
Electrical safety and essential electrical systems in health care facilities
NFPA 110
Emergency and standby power systems — testing and maintenance
CSA C22.2 No. 14 / UL 508
Industrial control equipment — contactors, controls and wiring
CSA C22.1
Canadian Electrical Code, Part I
Applications

Where It's Used

  • Hospitals and long-term care
  • Data centres
  • High-rise residential
  • Water and wastewater plants
  • Telecom
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

No. It is controlled to shed its load as soon as the building needs the generator, so it only takes power that would otherwise go unused.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need: