- 1Roof discharge fans
- 2Control room
- 3Cable entry panel
- 4ISO container body
Containerized & Medium-Voltage Load Bank
Load banks inside 20 or 40 ft containers: multi-megawatt resistive or resistive-reactive load at 480 – 600 V, or medium-voltage designs that connect straight to 4.16 – 13.8 kV gear.
Megawatts in a Box
Commissioning a data centre or a generator plant can mean testing tens of megawatts. Containerized load banks pack the elements, fans and controls into standard containers that ship by truck and set with a crane. Several can be controlled together from one station. Medium-voltage versions connect directly to the switchgear, avoiding a temporary step-down transformer.
- 20 or 40 ft ISO container body
- Roof-mounted vertical discharge fans
- Control room at one end
- Multiple units controlled together
- Low-voltage or direct medium-voltage connection
- Resistive or resistive-reactive
Containerized & Medium-Voltage Load Bank in plain words
What it does
Multi-megawatt load banks built into shipping containers — at low voltage, or connected straight to medium-voltage switchgear for large plants and data centres.
Pick it when
- You are testing several megawatts at once
- The generators or turbines run at medium voltage
- You want the load bank to ship and set like a container
Better choice if…
Under a megawatt, a trailer or stationary unit is simpler
See the Trailer-Mounted →What's Included
- Weatherproof container with access doors
- Cable entry panel
- Main breaker or MV switch
- Over-temperature, loss-of-airflow, fan-motor overload and control-power-loss protection; element fusing
- Climate-controlled control room
- +Reactive sections
- +Fibre-optic control between containers
- +Winter package
Full Specifications
| Parameter | Value |
|---|---|
| Rating | 1 – 6 MW per container (LV); MV units to suit |
| Voltage | 480 – 600 V, or 4.16 – 13.8 kV direct |
| Load type | Resistive or resistive-reactive |
| Housing | 20 or 40 ft container |
| Control | Local panel with kW, V, A, Hz readout; optional remote controller and PC software with data logging; multi-unit master control |
Built to Standard
Where It's Used
- Data centre commissioning
- Generator and turbine plants
- Utility and microgrid testing
- Mining power plants
From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.
- Engineering drawings and coordination studies
- Factory acceptance testing (FAT) with full reports
- Site commissioning and protection settings
- Spare parts, training, and maintenance support
Common Questions
Large generators and turbines often generate at 4.16 kV or 13.8 kV. A medium-voltage load bank connects straight to that switchgear, so no temporary transformer is needed and the test covers the real system.
Ready to Spec
Your Project?
Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:
- Total MW to test
- Voltage (LV or MV)
- Power factor needed
- Site access for containers
Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.
Request a Quote →Or call +1 (647) 616-2595