Arc-Resistant Metal-Clad Switchgear
Metal-clad gear reinforced to contain an internal arc and vent it through a plenum and duct, so people at the front, back and sides stay safe. IEEE C37.20.7 Type 2B.
When It Fails, It Fails Safely
An internal arc releases a blast of hot gas and molten metal in milliseconds. Arc-resistant switchgear is built to contain that: reinforced panels and doors, pressure-relief flaps and a plenum that collects the gases and sends them out through a duct to a safe place. Type 2B accessibility protects people at the front, back and sides, even with the low-voltage instrument door open. Combined with remote racking, it keeps operators out of harm’s way.
- Reinforced, latched doors and panels
- Pressure-relief flaps into a common plenum
- Exhaust duct to outside or a safe zone
- Type 2B: front, back, sides and LV door open
- Draw-out vacuum breakers, remote racking
- Arc-flash detection relays available
Arc-Resistant Metal-Clad Switchgear in plain words
What it does
Metal-clad switchgear built and tested to contain an internal arc and vent it safely away through a plenum — protecting anyone standing in front of it.
Pick it when
- Operators work in front of energized gear
- Your arc-flash study shows high incident energy
- Your owner’s standard calls for IEEE C37.20.7 gear
Better choice if…
Arc-flash exposure is low and cost matters most
See the Metal-Clad →What's Included
- Arc-resistant metal-clad construction
- Plenum and exhaust ducting designed for the room
- Vacuum breakers with stored-energy mechanisms
- Multifunction protection relays
- Copper bus, insulated
- ANSI 61 light grey powder coat (custom colours available)
- +Optical arc-flash detection
- +Remote racking and remote operation
- +Online thermal monitoring
- +Outdoor walk-in housing
Full Specifications
| Parameter | Value |
|---|---|
| Voltage class | 5, 15 and 27.6 kV |
| Main bus | 1,200 – 3,000 A |
| Arc rating | Up to 40 kA for 0.5 s |
| Accessibility | Type 2B per IEEE C37.20.7 |
| Breakers | Draw-out vacuum circuit breakers |
| Tests | Factory tests per IEEE C37.20 series: power-frequency withstand, mechanical operation, wiring and control checks, relay injection; witnessed FAT available |
Built to Standard
Where It's Used
- Process plants with operators near gear
- Mining and metals
- Hospitals and critical facilities
- Utility substations
From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.
- Engineering drawings and coordination studies
- Factory acceptance testing (FAT) with full reports
- Site commissioning and protection settings
- Spare parts, training, and maintenance support
Common Questions
Into a plenum above the lineup and then through a duct to the outdoors or a designated safe area of the room. We design the duct route with your building layout.
Ready to Spec
Your Project?
Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:
- Single-line diagram
- Arc-flash study or incident energy target
- Room layout for the exhaust duct
- Voltage, rating and fault level
Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.
Request a Quote →Or call +1 (647) 616-2595Often Compared With
Jump to any product
- Distribution Switchboard400 – 4,000 A · 600 V
- Service-Entrance Switchboard400 – 4,000 A · 600 V
- Main-Tie-Main1,200 – 4,000 A per main · 600 V
- Utility-Metered400 – 4,000 A · 600 V
- Integrated SwitchboardUp to 4,000 A · 15 – 500 kVA transformers
- Transfer Switch100 – 4,000 A · 600 V
- LV SwitchgearUp to 6,000 A · 600 V