We engineer and manufacture in Canada, respond fast, and are on call 24/7.

FIG. 01 · 3D
  1. 1Resistor elements
  2. 2Control panel
  3. 3Cam-lock connections
  4. 4Casters
Portable Load BankDWGCE-LDB-02-ISOVIEW3D ModelSCALENTSREV ACANDRON
AC Load Bank · Portable

Portable Resistive Load Bank

Adjustable resistive load on wheels for generator, UPS and transfer-switch testing. Fine load steps, digital metering and cam-lock connections. 25 – 500 kW.

25 – 500 kW208 – 600 V5 kW stepsCam-lock panelCasters
500 kW
Max rating
5 kW
Finest step
600 V
Max voltage
1–2
People to move
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Prove the Generator Before You Need It

A generator that has only ever idled has never been proven. A resistive load bank turns its output into heat, step by step, up to full rated power, so you can watch voltage, frequency and temperatures stay in line. Running at load also burns off the unburnt fuel and carbon (wet-stacking) that builds up in diesel engines run lightly. Our portable units roll in on casters, connect through a cam-lock panel and are controlled from the front panel or a remote controller.

  • Fine load steps for accurate testing
  • Digital kW, voltage, current and frequency readout
  • Cam-lock connection panel
  • Remote controller and data logging options
  • Indoor use, or outdoor in fair weather
  • Moves on casters with fork pockets
FIG. 02
Portable Resistive Load BankDWGCE-LDB-02-01VIEWHook-UpSCALENTSREV ACANDRON
Portable Resistive Load Bank · 25 – 500 kW · 208 – 600 V
In Plain Words

Portable Resistive Load Bank in plain words

What it does

A wheeled cabinet of heating elements and fans that puts a real, adjustable load on a generator or UPS so you can prove it carries full power.

Pick it when

  • You test generators at several sites
  • The test is indoors or in a parking garage, or outdoors in fair weather
  • One or two people need to move it without a crane

Better choice if…

The generator is large and the load bank should stay connected permanently

See the Stationary Outdoor →
Features & Upgrades

What's Included

Standard Features
  • Nickel-chromium resistive elements
  • Integral cooling fan
  • Voltage selector for 208 – 600 V
  • Main input breaker or fused disconnect
  • Over-temperature, loss-of-airflow, fan-motor overload and control-power-loss protection; element fusing
  • Powder-coated steel or aluminum cabinet
Optional Upgrades
  • +Remote handheld or PC control with test reports
  • +Weather hood for temporary outdoor use
  • +Reactive companion unit for 0.8 PF testing
  • +50/60 Hz operation
Technical Specifications

Full Specifications

ParameterValue
Rating25 – 500 kW
Voltage208, 240, 480 and 600 V AC, three-phase
Frequency60 Hz (50/60 Hz optional)
Load typeResistive, unity power factor
ControlLocal panel with kW, V, A, Hz readout; optional remote controller and PC software with data logging
ProtectionOver-temperature, loss-of-airflow, fan-motor overload and control-power-loss protection; element fusing
EnclosureIndoor / temporary outdoor
Standards & Compliance

Built to Standard

CSA C282
Emergency electrical power supply for buildings — includes periodic load testing
NFPA 110
Emergency and standby power systems — testing and maintenance
CSA C22.2 No. 14 / UL 508
Industrial control equipment — contactors, controls and wiring
CSA C22.1
Canadian Electrical Code, Part I
Applications

Where It's Used

  • Annual generator load tests
  • UPS and battery runtime checks
  • Commissioning new generators
  • Rental and service fleets
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

In Canada, CSA C282 sets periodic testing for emergency generators in buildings, including load testing; the authority having jurisdiction and your insurer may add requirements. A load bank lets you meet them even when the building load is too small.

When a diesel runs lightly loaded, fuel and carbon do not burn completely and collect in the exhaust. A few hours at a high load from a load bank burns them off and restores performance.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:

  • Generator or UPS size (kW)
  • Voltage and frequency
  • Indoor or outdoor use
  • How it will be moved
  • Control and reporting needs
Same-Day Response

Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.

Request a Quote →Or call +1 (647) 616-2595