Resistive, Reactive & Combined Load Testing

Load Banks

Portable and permanently installed load banks for validating generators, UPS systems, batteries, turbines, and complete electrical distribution systems under controlled load.

ResistiveReactive1 kW–30 MWPortable & Permanent
1 kW–30 MW
Capacity Range
Up to 15 kV
System Voltage
0.8–1.0 PF
Load Profiles
CSA / UL
Available
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Prove Performance Before It Matters

A load bank applies a precise electrical load so standby power equipment can be tested at operating conditions instead of at idle. CANDRON configures resistive, reactive, and combined systems around the source rating, desired power factor, duty cycle, cooling environment, and test procedure.

  • Generator, UPS, battery, and turbine testing under repeatable load
  • Portable, trailer-mounted, radiator-mounted, and permanent outdoor configurations
  • Local controls or automated load steps with remote monitoring and data capture
  • Custom connection panels, cam-locks, breakers, and cable management
Load Banks
Critical Power Distribution
Resistive, Reactive & Combined Load Testing
Features & Upgrades

What's Included

Standard Features
  • Heavy-duty resistor elements selected for the specified duty cycle
  • Branch circuit contactors and overcurrent protection for staged loading
  • High-capacity forced-air cooling with airflow and overtemperature protection
  • Digital metering for voltage, current, frequency, power, and power factor
  • Emergency stop, door interlocks, and loss-of-airflow shutdown
  • Weather-resistant enclosure options for permanent outdoor service
Optional Upgrades
  • +Reactive inductive load sections for 0.8 power-factor testing
  • +PLC/HMI controls with automatic test sequences and report export
  • +Remote operation over Modbus TCP, BACnet/IP, or hardwired I/O
  • +Trailer, skid, forklift-pocket, or radiator-mounted construction
  • +Medium-voltage transformer and switchgear integration
  • +Sound attenuation and cold-weather packages
Technical Specifications

Full Specifications

ParameterValue
Load TypeResistive, reactive, or combined resistive/reactive
Capacity1 kW to 30 MW; larger multi-module systems available
Voltage120 V to 600 V standard; medium-voltage systems up to 15 kV
Frequency50 Hz, 60 Hz, or dual-frequency configurations
Load StepsApplication-specific increments; manual or automatic sequencing
Power Factor1.0 resistive; 0.8 typical combined; other profiles available
DutyIntermittent, continuous, or application-specific test cycles
CoolingForced air with airflow proving and overtemperature protection
EnclosuresIndoor, NEMA 3R, NEMA 4, or application-specific
ControlsLocal switches, touchscreen HMI, remote I/O, or communications interface
Standards & Compliance

Built to Standard

UL 508A
UL 508A
Industrial control panel construction and control-system integration
CSA C22.2
CSA C22.2
Canadian electrical equipment and industrial control requirements
IEEE 446
IEEE 446
Recommended practice for emergency and standby power systems
NFPA 110
Emergency and standby power system testing requirements
Applications

Where It's Used

  • Generator commissioning and periodic exercising
  • Data centre UPS and integrated systems testing
  • Battery discharge and capacity testing
  • Hospitals and mission-critical facilities
  • Rental fleets and field service organizations
  • Marine, mining, oil and gas, and industrial plants
Load Banks installed in a working facility
Application View
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

A resistive load bank tests real power in kW at unity power factor. A reactive load bank adds inductive kVAR so the source is tested at a lower power factor, commonly 0.8, which more closely reproduces the electrical and mechanical loading of motors, transformers, and other site loads.

Yes. The load bank can be designed for direct medium-voltage connection or paired with a step-down transformer and appropriately rated switchgear. The correct approach depends on voltage, capacity, available fault current, portability, and the required test procedure.

Yes. PLC/HMI control can apply programmed load steps, monitor electrical and thermal conditions, time each stage, and export test results. Remote supervisory control can also be integrated through common industrial protocols.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:

  • Source type, kW/kVA rating, voltage, frequency, and power factor
  • Required load steps, test duration, and duty cycle
  • Portable, trailer-mounted, radiator-mounted, or permanent installation
  • Indoor/outdoor environment and site ambient conditions
  • Preferred controls, communications, and data-reporting requirements