Load Banks
Portable and permanently installed load banks for validating generators, UPS systems, batteries, turbines, and complete electrical distribution systems under controlled load.
Prove Performance Before It Matters
A load bank applies a precise electrical load so standby power equipment can be tested at operating conditions instead of at idle. CANDRON configures resistive, reactive, and combined systems around the source rating, desired power factor, duty cycle, cooling environment, and test procedure.
- Generator, UPS, battery, and turbine testing under repeatable load
- Portable, trailer-mounted, radiator-mounted, and permanent outdoor configurations
- Local controls or automated load steps with remote monitoring and data capture
- Custom connection panels, cam-locks, breakers, and cable management

What's Included
- Heavy-duty resistor elements selected for the specified duty cycle
- Branch circuit contactors and overcurrent protection for staged loading
- High-capacity forced-air cooling with airflow and overtemperature protection
- Digital metering for voltage, current, frequency, power, and power factor
- Emergency stop, door interlocks, and loss-of-airflow shutdown
- Weather-resistant enclosure options for permanent outdoor service
- +Reactive inductive load sections for 0.8 power-factor testing
- +PLC/HMI controls with automatic test sequences and report export
- +Remote operation over Modbus TCP, BACnet/IP, or hardwired I/O
- +Trailer, skid, forklift-pocket, or radiator-mounted construction
- +Medium-voltage transformer and switchgear integration
- +Sound attenuation and cold-weather packages
Full Specifications
| Parameter | Value |
|---|---|
| Load Type | Resistive, reactive, or combined resistive/reactive |
| Capacity | 1 kW to 30 MW; larger multi-module systems available |
| Voltage | 120 V to 600 V standard; medium-voltage systems up to 15 kV |
| Frequency | 50 Hz, 60 Hz, or dual-frequency configurations |
| Load Steps | Application-specific increments; manual or automatic sequencing |
| Power Factor | 1.0 resistive; 0.8 typical combined; other profiles available |
| Duty | Intermittent, continuous, or application-specific test cycles |
| Cooling | Forced air with airflow proving and overtemperature protection |
| Enclosures | Indoor, NEMA 3R, NEMA 4, or application-specific |
| Controls | Local switches, touchscreen HMI, remote I/O, or communications interface |
Built to Standard



Where It's Used
- Generator commissioning and periodic exercising
- Data centre UPS and integrated systems testing
- Battery discharge and capacity testing
- Hospitals and mission-critical facilities
- Rental fleets and field service organizations
- Marine, mining, oil and gas, and industrial plants

From design and specification through factory testing, commissioning, and ongoing maintenance — CANDRON delivers at every phase.
- Engineering drawings and coordination studies
- Factory acceptance testing (FAT) with full reports
- Site commissioning and protection settings
- Spare parts, training, and maintenance support
Common Questions
A resistive load bank tests real power in kW at unity power factor. A reactive load bank adds inductive kVAR so the source is tested at a lower power factor, commonly 0.8, which more closely reproduces the electrical and mechanical loading of motors, transformers, and other site loads.
Yes. The load bank can be designed for direct medium-voltage connection or paired with a step-down transformer and appropriately rated switchgear. The correct approach depends on voltage, capacity, available fault current, portability, and the required test procedure.
Yes. PLC/HMI control can apply programmed load steps, monitor electrical and thermal conditions, time each stage, and export test results. Remote supervisory control can also be integrated through common industrial protocols.
Ready to Spec
Your Project?
Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:
- Source type, kW/kVA rating, voltage, frequency, and power factor
- Required load steps, test duration, and duty cycle
- Portable, trailer-mounted, radiator-mounted, or permanent installation
- Indoor/outdoor environment and site ambient conditions
- Preferred controls, communications, and data-reporting requirements
Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.
Request a Quote →Or call us directly